only 2 power levels

Added by lionel corgnet over 2 years ago. Updated almost 2 years ago.

Status:
Closed
Priority:
Normal
Assignee:
-
Category:
-
Target version:
-
Start date:
08/22/2022
Due date:
% Done:

0%

Estimated time:
Chirp Version:
daily
Model affected:
Baofeng UV-5R
Platform:
Windows
Debug Log:
I read the instructions above:

Description

On my UV-5R I can chose 3 levels : low / medium / high.
With chirp, when choosing a channel and editing the preferences, I have only 2 levels : low/high
Between a .img and the radio :

  • high => high
  • low => medium
  • and nothing for low (I wish I'm understandable :-)

Could there be a third option in chirp, so that the 3 levels could be set/recorded in a .img file ?

Actions #1

Updated by Jim Unroe over 2 years ago

  • Status changed from New to Feedback

You are not selecting the correct Vendor / Model.

The rule of thumb is...
2 Power Levels, 2 Bands = Vendor: Baofeng / Model: UV-5R
3 Power Levels, 2 Bands = Vendor: Baofeng / Model: BF-F8HP
2 Power Levels, 3 Bands = Vendor: Radioddity / Model: UV-5RX3

Jim KC9HI

Actions #2

Updated by lionel corgnet over 2 years ago

I can read on the radio "BAOFENG" and "UV-5R"
3 + power on = " Ver "."BFB298 "
"Firmware message 1" = "HN5RV01" ; "Firmware message 2" = "1"
In menu 2, TXP can be set to LOW/MED/HIGH = 3 Power Levels

Jim Unroe wrote:

You are not selecting the correct Vendor / Model.

Should I really try anything else than Baofeng / UV-5R ?

Actions #3

Updated by Jim Unroe over 2 years ago

lionel corgnet wrote:

I can read on the radio "BAOFENG" and "UV-5R"
3 + power on = " Ver "."BFB298 "
"Firmware message 1" = "HN5RV01" ; "Firmware message 2" = "1"
In menu 2, TXP can be set to LOW/MED/HIGH = 3 Power Levels

Jim Unroe wrote:

You are not selecting the correct Vendor / Model.

Should I really try anything else than Baofeng / UV-5R ?

From the "rule of thumb" chart that I provided above, you must use Baofeng / BF-F8HP to get support for 3 transmit power levels.

Jim KC9HI

Actions #4

Updated by Bernhard Hailer almost 2 years ago

  • Status changed from Feedback to Closed
  • Model affected changed from UV-5R to Baofeng UV-5R

Solution provided.