I read the instructions above:

Description

My newly received UV-5R-3 from MTC gives the error message "not the amount of data we want" when I try to read from the radio. I am selecting the BTECH 5X3 series per issue/patch 5309. In reviewing the patch code it appears the firmware may have changed as my firmware shows as UVV30. I am using a genuine BTECH PC03 FDTI cable. The radio reads and writes ok using the Baofeng software. Debug log attached.


Files

debug.log (22.4 KB) debug.log Jim Faline, 04/13/2018 11:51 AM
Actions #1

Updated by Jim Faline over 6 years ago

firmware is UVV306

Actions #2

Updated by Jimmy Vance over 6 years ago

I was asked to program a couple of MTC UV-5R-3. I get the same error message reported here, the debug file looks the same, and the radios also show firmware UVV306

Actions #3

Updated by Jim Unroe over 6 years ago

  • Status changed from New to Feedback

You are not selecting the correct Vendor/Model. It is not a BTech UV-5X3.

Vendor: MTC
Model: UV-5R-3

Jim KC9HI