Project

General

Profile

Actions

Bug #3587

closed

QYT KT8900 : Clone failed: Invalid header for block 0x0000:

Added by Clive Hornback over 8 years ago. Updated over 4 years ago.

Status:
Closed
Priority:
Normal
Assignee:
-
Category:
-
Target version:
-
Start date:
04/18/2016
Due date:
% Done:

0%

Estimated time:
Chirp Version:
daily
Model affected:
QYT KT-8900R
Platform:
Linux
Debug Log:
I read the instructions above:

Description

download failed with the following error

(process:10948): Gtk-WARNING **: Locale not supported by C library.
Using the fallback 'C' locale.
WARNING: Short reading 20 bytes from the 21 requested.
ERROR: -- Exception: --
ERROR: Traceback (most recent call last):
File "/usr/lib/python2.7/dist-packages/chirp/ui/clone.py", line 238, in run
self.__radio.sync_in()
File "/usr/lib/python2.7/dist-packages/chirp/drivers/btech.py", line 784, in sync_in
data = _download(self)
File "/usr/lib/python2.7/dist-packages/chirp/drivers/btech.py", line 575, in _download
d = _recv(radio, addr)
File "/usr/lib/python2.7/dist-packages/chirp/drivers/btech.py", line 411, in _recv
raise errors.RadioError("Invalid header for block 0x%04x:" % addr)
RadioError: Invalid header for block 0x0000:

ERROR: ----------------
ERROR: Clone failed: Invalid header for block 0x0000:
ERROR: --- Exception Dialog: Invalid header for block 0x0000: ---
ERROR: None

USB device cable recognized as the following.

[98971.748022] usb 4-1: new full-speed USB device number 3 using uhci_hcd
[98972.114048] usb 4-1: New USB device found, idVendor=067b, idProduct=2303
[98972.114056] usb 4-1: New USB device strings: Mfr=1, Product=2, SerialNumber=0
[98972.114061] usb 4-1: Product: USB-Serial Controller
[98972.114066] usb 4-1: Manufacturer: Prolific Technology Inc.
[98972.117157] pl2303 4-1:1.0: pl2303 converter detected
[98972.129196] usb 4-1: pl2303 converter now attached to ttyUSB0


Files

debug.log (17.8 KB) debug.log Clive Hornback, 04/18/2016 02:36 PM

Related issues 1 (0 open1 closed)

Related to Bug #3993: Error when downloading from QYT KT-8900RClosedPavel Milanes09/05/2016

Actions
Actions #1

Updated by Michael Wagner over 8 years ago

Please take a look at http://chirp.danplanet.com/issues/3993 - that ticket is a duplicate (with a potential fix).

Actions #2

Updated by Bernhard Hailer over 4 years ago

  • Status changed from New to Closed
Actions #3

Updated by Bernhard Hailer over 4 years ago

  • Model affected changed from QYT KT8900 to QYT KT-8900R

Fixed, see #3993.

Actions

Also available in: Atom PDF