Wouxun KG-UV8D - channel name and other data lost when moving frequencies to another channel

Added by Rick Savoia about 10 years ago. Updated over 4 years ago.

Status:
Closed
Priority:
Normal
Assignee:
Category:
-
Target version:
Start date:
10/16/2014
Due date:
% Done:

0%

Estimated time:
Chirp Version:
daily
Model affected:
Wouxun KG-UV8D
Platform:
All
Debug Log:
I read the instructions above:

Description

When moving a frequency up or down more than one channel, the name, PL tones and other data are replaced with the data in the channel the frequency is moved to. For instance, if moving the frequency from channel 9 to channel 2, the first move up to channel 8 seems to move all the data, however, as the frequency is moved up to the next channel, some of the other data is not moved with it, retaining the channel name and tone settings of the channel it is moved to. If it is moved down to an empty channel, it uses the default tone data of the empty channel.


Files

debug.log (16.5 KB) debug.log Rick Savoia, 10/16/2014 07:35 AM

Related issues 1 (0 open1 closed)

Related to Bug #1973: Wouxun KG-UV8D import from data sourceClosedRon Wellsted10/16/2014

Actions
Actions #1

Updated by Ron Wellsted about 10 years ago

  • Status changed from New to In Progress
  • Assignee set to Ron Wellsted
  • Target version set to 0.5.0

Problem confirmed, Investigation in progress

Actions #2

Updated by Bernhard Hailer almost 5 years ago

This might be complete? Can we close the ticket?

Actions #3

Updated by Bernhard Hailer over 4 years ago

  • Status changed from In Progress to Closed
  • Model affected changed from KG-UV8D to Wouxun KG-UV8D
  • Platform changed from Windows to All

I believe #1973 fixes this. Please let us know in case this problem still exists.