New Model #1489 » kg-uv950pl_protocol.txt
1 |
Serial comms are at 19200 baud, 8N1 |
---|---|
2 |
The data is passed in variable length records |
3 |
Record structure: |
4 |
Offset Usage |
5 |
0 start of record (\xda) |
6 |
1 Command |
7 |
2 direction (\xff PC-> Radio, \x00 Radio -> PC) |
8 |
3 length of payload (excluding header/checksum) (n) |
9 |
4 payload (n bytes) |
10 |
4+n+1 checksum |
11 |
|
12 |
Commands: |
13 |
\x80 Start comms/Identify |
14 |
\x81 End comms & Reboot |
15 |
\x82 Config read |
16 |
\x83 Config write |
17 |
\x84 Read memory |
18 |
\x85 Write memory) |